Motor Saver 201-575-AU Fiche technique Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 88
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
www.symcom.com • 800-843-8848 • fax: 605-348-5685
44
Available Models:
Features:
DIN rail or surface mountable
Unique probe protection algorithm
Invertible relay logic for use in pump-up
and pump-down applications
Adjustable debounce timer
Microcontroller based
2 relay contacts
LED status indicators
A
pprovals:
Specications
460-15-100-LLS
The Model 460-15-100-LLS
is a liquid level sensor to detect the presence
of conductive liquids. A probe is mounted
at the desired tank level and connected to the
PumpSaver
®
. When the probe is submersed, the
PumpSaver’s output contacts will change state as
soon as the debounce time expires. The adjustable
debounce timer is intended to prevent nuisance
actuating due to waves or splashing in the tank.
Relay logic can be inverted so the PumpSaver’s
output contacts change state when the probe is no
longer submersed. This makes the unit versatile for
use in pump-up and pump-down applications.
For more information see:
See Appendix A, page 69, Figure 11 for dimensional
drawing.
See Appendix B, page 79, Figure 39 for typical
wiring diagrams.
Model 460-15-100-LLS
single-channel liquid level sensor, din rail mount, adjustable debounce timer
Liquid Level Sensor
Surge
IEC ...........................................IEC 61000-4-5, Level 3, 4kV line-to-line;
Level 4, 4kV line-to-ground
ANSI/IEEE ....................................C62.41 Surge and Ring Wave Compliance to
a level of 6kV line-to-line
Hi-Potential Test ...............................Meets UL508 (2 x rated V + 1000 V for 1 min.)
Safety Marks
UL ............................................UL508 (File #E68520)
CE ............................................IEC 60947
Enclosure ......................................Polycarbonate
Dimensions ....................................3.5” H X 2.084” W X 2.350” D
(88.9 x 52.93 x 59.69mm)
Weight ........................................1 lb. (16 oz., 453.59 g)
Mounting Method ..............................35mm DIN rail or Surfact Mount
(#6 or #8 screws)
*Note: 50Hz will increase all delay timers by 20%
Input Characteristics
Control Voltage .................................110/120VAC nominal
Frequency .....................................50*/60Hz
Sensitivity .....................................100kΩ
Functional Characteristics
Probe Sense Voltage ............................5vdc pulsed
Debounce Time Delay ...........................2-60 seconds
Output Characteristics
Output contact Rating – (Two Form A - DPST)
Pilot Duty .....................................360VA @ 240VAC
General Purpose ................................8A @ 240VAC
General Characteristics
Ambient Temperature Range
Operating .....................................-40° to 70°C (-40° to 158°F)
Storage ........................................-40° to 80°C (-40° to 176°F)
Maximum Input Power ..........................2 W
Class of Protection ..............................IP20, NEMA 1 (finger safe)
Relative Humidity ..............................10-95%, non-condensing per IEC 68-2-3
Terminal Torque. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 in.-lbs.
Wire ..........................................12-20 AWG
Standards Passed
Electrostatic Discharge (ESD) .....................IEC 61000-4-2, Level 3, 6kV contact,
8kV air
Radio Frequency Immunity, Radiated .............150MHz, 10 V/m
Fast Transient Burst IEC .........................61000-4-4, Level 3, 3.5kV input
power and controls
CATALOG_SYMCOM_2014.indd 44 6/10/14 11:06 AM