www.symcom.com • 800-843-8848 • fax: 605-348-5685
12
Features:
Can be used in both new and existing
installations
Can be used as stand-alone or with a 777 Plus
series unit
Can be re-configured to work with standard 777
units
Reduced field wiring. Simple Ethernet
jack
connection for network
10 Base-T Ethernet
compatible
• Additional Modbus port and Modbus message
assembly feature for block reads
Ease in system startup and commissioning
Additional remote reset input to reset 777
Plus series
Flexible addressing standard
Approvals:
Available Models:
Specications
CIO-EN
The CIO-EN Module (non-POE)
is a convenient and cost-effective Modbus-TCP
and Modbus-RTU interface capable of providing
discrete control and monitoring of an overload
relay over a Modbus network.
For more information see:
See Appendix A, page 66, Figure 3 for dimensional
drawing.
Input Characteristics
Power Requirements
Voltage .......................................24VDC +10%
Current .......................................95mA (max.) 70mA (typical)
Power ........................................2.28 W (max.) 1.7 W (typical)
Digital Inputs
General Purpose (4)
Voltage Range ................................. 12-24VDC
Current .......................................2mA (typical)
Functional Specications
Remote Reset (for use with optional 777 Series) ....Normally open pushbutton rated 24VDC,
10mA (min.)
Ethernet Controller ............................IEEE 802.3
Capability ....................................10Base-T
Output Characteristics
SPDT (1), SPST (1)
Pilot Duty ....................................480VA & 240VAC, B300
General Purpose ...............................5A @ 240VAC
General Characteristics
Ambient Operating Temperature ................
-20° to 70°C (-4° to 158°F)
Terminal (depluggable terminal block)
Torque .......................................3 in.-lbs. (max.)
Wire AWG .................................... 12-20 AWG
Class of Protection .............................IP20, NEMA 1 (nger safe)
Relative Humidity .............................10-95%, non-condensing per IEC 68-2-3
Standards Passed
Electrostatic Discharge (ESD) ....................IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity, Radiated ............150 MHz, 10V/m
Fast Transient Burst ............................IEC 61000-4-4, Level 3, 4kV input power
Hi-Potential Test ............................... Meets UL508 (2 x rated V + 1000V for 1 min)
Surge
Input Power ..................................IEC 61000-4-5, Level 1
Inputs/Data Lines .............................IEC 61000-4-5, Level 2
Safety Marks
UL ...........................................UL508 (File #E68520)
CSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C22.2 (File #46510)
CE ...........................................IEC 60947-6-2
Enclosure .....................................Polycarbonate
Dimensions ...................................2.08”H x 2.776”W x 0.77”D
Weight .......................................0.25 lb. (4 oz., 113.4 g)
Mounting Methods .......................... DIN Rail or surface mount (w/ two #8
screws)
Features:
Powered by the 777-AccuPower
Scalable 4-20mA output proportional to Hp or kW
Signal can be used for displays, controllers, or
PLCs
Approvals:
Output Characteristics
Current ......................................4-20mA
General Characteristics
Temperature Range ...........................-20
o
to 50
o
C (-4
o
to 122
o
F)
Terminal (depluggable terminal block)
Torque ......................................3 in.-lbs. (max.)
Wire AWG ...................................12-20 AWG
Class of Protection ............................IP20
Relative Humidity ............................10-95%, non-condensing per IEC 68-2-3
Standards Passed
Electrostatic Discharge ........................IEC 61000-4-2, Level 3, 6kV contact,
8kV air
Radio Frequency Immunity, Radiated ...........150 MHz, 10V/m
Fast Transient Burst ...........................IEC 61000-4-4, Level 3, 4kV input power
Hi-Potential Test ..............................Meets UL508 (2 x rated V + 1000V
for 1 min)
Surge
Input Power .................................IEC 61000-4-5, Level 1
Inputs/Data Lines ............................IEC 61000-4-5, Level 2
Safety Marks
UL ..........................................UL508 (File #E68520)
CE ..........................................IEC 60947
Enclosure ....................................Polycarbonate
Dimensions ..................................2.08”H x 2.90”W x 0.77”D
Weight ......................................0.25 lb. (4 oz., 113.4 g)
Mounting Method ............................#8 screws; mount to side of
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 777-AccuPower unit
Available Models:
Specications
COM 4-20
The Com 4-20mA Output Module
is intended for use with ONLY the Model
777-AccuPower output power monitor. The
module will send a 4-20mA signal proportional
to the output power. It can also be used to
send the input power by setting the efficiency
setting on the 777-AccuPower monitor to one.
This module allows communication to a PLC
with an analog input and no Modbus input.
For more information see:
See Appendix A, page 66, Figure 2 for
dimensional drawing.
Communication Modules
Models CIO-EN / COM 4-20mA
communication link to PLC/SCADA/monitoring systems
CATALOG_SYMCOM_2014.indd 12 6/10/14 11:06 AM